Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

frieser

Starting Member

1

Thursday, April 27th 2017, 3:15pm

Rain Bird ESP-ME Controller

I have Rain Bird ESP-ME Controller. About 1 year old. I have 7 zones. Zone #4 with not operate properly. Zone #4 will operates normal when placed in manual mode. However when in automatic mode the spray heads have a very low flow. I installed a new top works on the valve body. No changes. Checked the VAC at the controller terminals and all 7 valves have 27.3 volts in manual and automatic. I'm stumped on why zone #4 won't spray properly on automatic mode. Any ideas why? 8)

mrfixit

Moderator

Posts: 2,002

Location: USA

2

Thursday, April 27th 2017, 8:35pm

It sounds like two valves are running at the same time.
Are you sure valve 4 is the only one running when the pressure's low?
Maybe swap the number 4 valve wire with the number 1 wire. See if you still have the same problem.
Maybe vavel 3 is slow to turn off.