Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

notmechanical

Starting Member

1

Tuesday, April 25th 2017, 6:23pm

Only 1 Zone out of 5 is watering

Hi Forum,

Thank you in advance for any help you can provide. We have an older Rainbird E-9i model controller. The issue is simple, only 1 out of the 5 zones waters. Whats even stranger is that when I do a manual test, no matter which zone I choose, it activates that one zone (zone 2) that works. So when we go through the auto water schedule, the one working zone gets watered 5 times in a row. It worked fine before....

I have no clue where to even begin to troubleshoot. Thanks for any help.

Jay

mrfixit

Moderator

Posts: 2,002

Location: USA

2

Wednesday, April 26th 2017, 12:07am

First of all you need to determine if the controller's ok. Turn on any valve but number 2. Let's say number 3. You turn on 3 and zone 2 runs. Now disconnect the wire from the number 3 terminal, did zone 2 stop watering?

If not your timer's shot.

If so the wiring's messed up. Redo all the connections at the valves. Make sure they're hooked up correctly.