Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Hawkman

Starting Member

1

Sunday, July 29th 2018, 3:20pm

1 or more zones coming on

I have 16 zones. The first three come on by themselves. When i go to turn the rest of them on the #3 zone comes on again so i have 2 zones coming on at once all the time. Is that a manifold issue cause the wiring has never changed.

mrfixit

Moderator

Posts: 2,318

Location: USA

2

Sunday, July 29th 2018, 7:26pm

If you have a master valve I'd say the number 3 valve needs repair.

Find the number 3 valve and disconnect one of the wires from the solenoid.
Now go back to the controller and turn on a station. Does number 3 still come on?
Yes = the valve's bad.
No = the wiring's crossed.