]Sorry you're having such a bad experience, it shouldn't have to be that way!! First off, on a well and pump system, the design psi. and flow needs to be measured at the supply point (where the mainline accually connects to the water line before the backflow preventer). Secondly, you need to know the psi drop in all of the components within the zone (backflow, valve, piping). Third, what is the desired distance for each head to be suppling water (which will demand a min. psi and gpm at the head for proper coverage based on distance between heads, this info will be provided by the manuf. of the head)
Please provide this info, maybe your system can be salvaged. About you not getting what was agreed on, hope you got a contract with the contractor.