You are not logged in.

Twh999

Starting Member

1

Thursday, May 18th 2017, 1:42pm

Hunter pro C controller only displaying zones 1-4

While in the set program start time the display will only show zones 1-4.
While in manual mode I can see all 9 zones.
I have unplugged power, removed battery and slid out all three modules for 5 mins.
When I start again it is the same thing.
Any suggestions?

mrfixit

Moderator

Posts: 1,994

Location: USA

2

Thursday, May 18th 2017, 10:33pm

We see this question all the time so you're not alone.
What you're seeing are the start times. 1-2-3-4.
You only need to program ONE start time then the valves will run in sequence for the amount of time you've programmed in under "run times". You program all 9 under run times.