Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 10 posts

Thursday, September 6th 2012, 10:33pm

by Wet_Boots

RE: How to set up sprinkler heads with motion detectors

We have a nice grassy area in front of an apartment building in Denver that the transient drunks seem to enjoy sleeping on...needless to say, it really is becoming a problem for the "tenant happiness" factor, especially for our young single women. Is there a way to add a motion detector onto a head or two that has a time delay of 30 seconds or so before clicking on? Any help is appreciated. Thanks, Linda
It might be easier to set up motion detectors and some speakers playing really annoying music. Some convenience stores got rid of loiterers with stuff like Lawrence Welk.

Thursday, September 6th 2012, 10:50am

by Lstrath

How to set up sprinkler heads with motion detectors

We have a nice grassy area in front of an apartment building in Denver that the transient drunks seem to enjoy sleeping on...needless to say, it really is becoming a problem for the "tenant happiness" factor, especially for our young single women. Is there a way to add a motion detector onto a head or two that has a time delay of 30 seconds or so before clicking on? Any help is appreciated. Thanks, Linda

Wednesday, July 18th 2012, 8:39am

by Wet_Boots

So if that's the first thing to check then why did you recommend they move the number 3 wire around as a first step.
Moving a zone wire to another station does not require a multimeter.

Tuesday, July 17th 2012, 11:15pm

by mrfixit

So if that's the first thing to check then why did you recommend they move the number 3 wire around as a first step.

Tuesday, July 17th 2012, 9:17pm

by Wet_Boots

When encountering non-opening zones with these old controllers, it pays to check the controller output first. Sometimes the non-opening is only temporary, as the 'timing wheel' slowly turns, and the wafer switch contacts finally close.

Tuesday, July 17th 2012, 7:17pm

by mrfixit

Ok, Don't double check your wiring.

Tuesday, July 17th 2012, 3:24pm

by Wet_Boots

Try resplicing the ground wire.
there is a zone-failure mode in old electro-mechanical controllers, due to poor continuity in the wafer-switch assembly - it might be remedied by cleaning the contacts, but some of them are passing line voltage, so fiddlers beware 8o

Tuesday, July 17th 2012, 11:30am

by mrfixit

Try resplicing the ground wire.

Tuesday, July 17th 2012, 7:34am

by Wet_Boots

RE: Stuck

Have imperial controller with brass valves (6 zones). Zone three was not coming on so I replaced with a Rainbird inline valve. Then I could not get that valve to shut regardless of what zone controller was on - after bleeding got zone to shut but cannot get any others to activate on their respective zones. Now just puzzled???
there was probably nothing wrong with the valve you replaced. You should try connecting the zone 3 wire to another (unused) controller station. This is a problem, of course, if you are already using all 6 zones of the controller.

Monday, July 16th 2012, 9:29pm

by Puzzled (Guest)

Stuck

Have imperial controller with brass valves (6 zones). Zone three was not coming on so I replaced with a Rainbird inline valve. Then I could not get that valve to shut regardless of what zone controller was on - after bleeding got zone to shut but cannot get any others to activate on their respective zones. Now just puzzled???