Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 2641 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 2 posts

Thursday, September 6th 2007, 2:49am

by Wet_Boots

50 psi is kind of low for I-25 heads. You can flow 20 gpm through a one-inch valve, and lose less than 5 psi. You could also flow 30 gpm, but the pressure losses begin to go way up.

Tuesday, September 4th 2007, 11:01am

by SteveSchemenauer@aol.com

Flow Rates

I have a 1.5" main with 50 lbs of pressure

I would like to be able to use the Hunter 1-25 heads, which I am told use about 13 gpm

What I do not know is the flow rate through a 1" Valve.... thus how many heads can a 1" valve support

(I am trying to avoid buying 1.5" valves