Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.
Attention: The last reply to this post was 2219 days ago. The thread may already be out of date. Please consider creating a new thread.
The last 8 posts
Thanks for the info.[

]
Flow controls work to restrict water flow as mentioned before. I find them very useful for two puposes: reglate pressure at the heads so they don't fog, and to restrict the flow thru valves giving backpressure so the cavity area above the diaphragm can build pressure and the valve can close properly. Drip valves, in particular, have a real problem getting enough back pressure to close, especially if there's a very small volume flowing through the zone to start with. There HAS TO BE a differential of pressure between upstream and downstream sides of the valve or it won't close.... period. By restricting the flow through the bibb/valve seat, that differential is acheived. (I'm generally talking PIN type valves here, of course.)
Bill
Just thought that most strip heads are 4x15 pattern. Dont you have to have head to head coverage?
Or use a double row of strip nozzles.
Why don't you use 8' nozzles instead of the 12'?
As I understand it, flow control is when a valve has a knob that you use to restrict the flow of water through the valve. It essentially works like turning your hose bibb way down. Same thing with your sinks. You turn the knob on just a little to get a little water, or on full to get as much water as possible. When a valve doesn't have flow control, it basically means it acts like a sink knob with two positions, off and on.
The reason I ask is I am planning on using some sprays on a 7'X65' strip. I was told anything under 12' radius would mist badly. So I'm trying to find out if I can use 12' sprays and reduce radius with flow control on valve? I have 53 psi and plan on running 10-12gpm per zone.
Educate me on use of a flow control
Can someone please tell me what a flow control is for? I know it reduces water flow, but does it reduce pressure?