Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.
Attention: The last reply to this post was 3666 days ago. The thread may already be out of date. Please consider creating a new thread.
The last 4 posts
Hi,
That is called Low Head Drainage, it is when the water is acutally draining out of the line, and out of the sprinkler head, although this should not always be continous, if this happens 24/7, after the sprinklers are off you have a leaking valve. The vavles i use are awesome and are the Irritrol 2400T valves
Ray
Rays Above and Beyond Automatic LAwn Sprinklers
Raymond Padula Jr.
The control valve for that zone may not be shutting off all the way or "weeping" as I call it. If so, the valve will need to be rebuilt or replaced. If this is the case, the check valve will not work.
Most of the time this is the cause.
Sprinkler Solutions, Inc.
Arizona and Colorado
www.sprinklersolutions.net
<img src="http://www.sprinklersolutions.net/files/logo.jpg width=216 height=53 border=0" border=0>
Install a Huner Check Valve (HCV) or any kind of check valve on the last sprinkler. Screw the sprinkler off, put a shorter riser on, or lower your swimg pipe or swing joint lower and screw the check valve on then screw the sprinkler on top of that. The reason I tell you to lower your riser, swing joint, etc. is because the check valve will raise the height of your sprinkler.
Leaking pop-up
The last pop-up on one line is leaking at the center when not turned on. Seems to not be sealing. I have changed the sprinkler top with a new one and the problem is still there. Any suggestions?
Elsyne Epps