Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 2 posts

Thursday, July 27th 2017, 8:44am

by BackflowInspector

Its probably a flow problem
You may have too much water flowing through the the 2 zones that are giving you the problems with pressure.
Think of it like a garden hose with a couple of holes in it, you will have too much water flowing out the holes and not enough at the end of the hose.

If you exceed the capacity of your 3/4" line, Probably 8-10 gallons per minute, you will have very poor performance.

If that sounds like a reasonable explanation you may either want to split the zones into more zones or find a way to reduce the flow with water conservation heads like the Hunter MP Rotator or the Toro Precision Series Spray Nozzle.

Good Luck

Wednesday, July 26th 2017, 8:43pm

by blckblttkd

New system has two zones with low pressure

Hey folks! Really happy I stumbled on this site. I am looking for some ideas here. Pretty stumped at the moment.

The system:
I expanded a 3 zone system to 9 zones. To do this, I added the following two pre-built manifolds:

https://www.amazon.com/dp/B001H1NGOI/ref=asc_df_B001H1NGOI5093959/?tag=hyprod-20&creative=394997&creativeASIN=B001H1NGOI&linkCode=df0&hvadid=167139575215&hvpos=1o2&hvnetw=g&hvrand=3780701033257310822&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9028753&hvtargid=pla-306024075728


Using a new Rachio Gen2 16 zone controller.

All piping and joints for zones 4-9 are brand new 3/4" flex pipe.

The supply line from the house water main is also 3/4". My house has a steady 80psi.

The problem:
2 zones are for garden areas, the remaining zones are for my lawns (front and back between all of them). Each zone for grass has 6 or less fixed spray head sprinklers (Orbit brand again).

Zones 5 and 6 have about half the pressure the others do. None of the heads on either of those two zones pop up all the way, or spray their full range like the others.

Attempts made to fix it:
1) I swapped solenoids out between a full pressure zone and zone 5. No change. So, not a solenoid problem.
2) Replaced diaphragms, no change.
3) Inspected the valve housing, no dirt (shouldn't be it's brand new!), nothing of significance.
4) Manually turning the solenoid on gives the same low pressure. So with the above it does not seem like a valve problem.

What else can I try?

Thanks!