Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 2690 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 8 posts

Sunday, April 22nd 2007, 8:42pm

by boo

Thanks for the info.[:D]

Wednesday, April 18th 2007, 5:34am

by Bill Painter

Flow controls work to restrict water flow as mentioned before. I find them very useful for two puposes: reglate pressure at the heads so they don't fog, and to restrict the flow thru valves giving backpressure so the cavity area above the diaphragm can build pressure and the valve can close properly. Drip valves, in particular, have a real problem getting enough back pressure to close, especially if there's a very small volume flowing through the zone to start with. There HAS TO BE a differential of pressure between upstream and downstream sides of the valve or it won't close.... period. By restricting the flow through the bibb/valve seat, that differential is acheived. (I'm generally talking PIN type valves here, of course.)
Bill

Tuesday, April 10th 2007, 10:31pm

by boo

Just thought that most strip heads are 4x15 pattern. Dont you have to have head to head coverage?

Tuesday, April 10th 2007, 4:48am

by Wet_Boots

Or use a double row of strip nozzles.

Tuesday, April 10th 2007, 3:37am

by Tom

Why don't you use 8' nozzles instead of the 12'?

Monday, April 9th 2007, 8:02pm

by HooKooDooKu

As I understand it, flow control is when a valve has a knob that you use to restrict the flow of water through the valve. It essentially works like turning your hose bibb way down. Same thing with your sinks. You turn the knob on just a little to get a little water, or on full to get as much water as possible. When a valve doesn't have flow control, it basically means it acts like a sink knob with two positions, off and on.

Monday, April 9th 2007, 7:28pm

by boo

The reason I ask is I am planning on using some sprays on a 7'X65' strip. I was told anything under 12' radius would mist badly. So I'm trying to find out if I can use 12' sprays and reduce radius with flow control on valve? I have 53 psi and plan on running 10-12gpm per zone.

Thursday, April 5th 2007, 9:40pm

by boo

Educate me on use of a flow control

Can someone please tell me what a flow control is for? I know it reduces water flow, but does it reduce pressure?