Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 5 posts

Wednesday, July 4th 2018, 9:27pm

by RichMoney

You can also install a pop off valve on the pump or somewhere in the main line. Once the pressure reaches a specified point it will dump water out of the valvle.

https://sprinklerresource.com/

Friday, June 15th 2018, 9:39am

by Wet_Boots

A delay unit might solve a pressure spike issue, but the pressure tank is your best bet, because of it providing a physical shock absorber to the plumbing. Also, the classical no-pump-relay-needed supply will have a pressure tank and a pressure switch, with a large enough tank giving you an always-pressurized water supply you might be able to use for things other than lawn watering.

Wednesday, June 13th 2018, 4:11pm

by Mudman

Pressure Switch Question

Thanks Wet_Boots, much appreciated. A small pressure tank upstream of the pressure switch should do it. I tried a different approach without success. I disconnected the pump wire from the controller and started the timer, assuming it would open the valves. After 5 minutes I reinserted the pump wire into the controller. No luck, the pressure still spiked. I then went to the pump, reset the pressure switch and everything worked fine. My thought was if that worked I could install a ON DELAY timer relay between the timer and the pump. Any thoughts on why that didn't work?

Wednesday, June 13th 2018, 9:12am

by Wet_Boots

Some controllers can energize a master valve or pump terminal a second or so a zone terminal energizes. You may need a small pressure tank alongside the pressure switch in order to ride out this pressure spike.

Tuesday, June 12th 2018, 7:38pm

by Mudman

Pressure Switch Question

Recently some mice ate through wires in one of my valve boxes causing a valve to not open. The pump didn't like this and eventually broke open a union downstream of the pump discharge. To avoid this in the future, I installed a pressure switch on the pump discharge to shut off the pump if the pressure exceeded the ordinary operating range of 35-45 psi. I set the pressure switch at 55 psi. However, when my orbit timer starts the pump there is a large (70 psi +) pressure spike which immediately shuts down the pump. What's interesting is that if I press the pressure switch reset button the pump works perfectly. Why the pressure spike when the timer turns on the pump but not when I reset the pump? Any help would be much appreciated.