Reply
Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.
Attention: The last reply to this post was 5454 days ago. The thread may already be out of date. Please consider creating a new thread.
The last 10 posts
If it is an irritrol 2400T thats easy to fix. Go online to sprinklerwarehouse and buy on. When it comes unsrew the bonnet. (Grey Ring) and pull out all the insides and top including the black ring. Then bring that outside to the bad valve. Unscrew the bad valve and then put in the new valve, into the old body (before putting the new guts in flush the valve. Also shut off the water before doing this) Then scew the bonnet on nice and tight, re wire, and turn on the water. If that dosnt work check your timer and wiring. HOpe that helps. Where are you located?
Thanks
Ray
Rays Above and Beyond Automatic Lawn Sprinklers
rob-
Did you replace the soleniod or the valve itself?
What kind of valve is it?
Thanks
Ray
Rays Above and Beyond Automatic Lawn Sprinklers
I would just replace the valve. Go to either Sprinkler Warehouse's online store and order the replacement before it gets too dry.
Thanks again!
Ok now I switched valve 6 & 7 and when I turn the water supply on zone 6 runs continuously while zone 7 stays off. Looks more and more like a bad valve / solenoid from the original zone 7. Agree? Thanks.
Irritrol Total Control 9 station. I disconnected the power and had the same behavior as before.
What kind of controller do you have?
I unscrewed, cleaned and reassembled. The problem still persists. I also noted this situation (I assume this was like this before). It is the zone 7 valve that runs continuously in the "off" position. If I turn this valuve "on" then zone 6 begins to run continuously even though the zone 6 valve is "off".
All valves "off" - zone 7 runs continuously
Valves 1-6 "off", zone 7 "on" - zones 6 & 7 run continuously
Any idea why this happens?
Does the diaphragm just screw off by hand, or do you need any tools?