Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 4515 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 3 posts

Friday, March 22nd 2002, 9:58am

by SprinklerGuy

I probably wouldn't recommend using a 1 inch mainline when you are supplying it with 1/2 inch copper! You will have trouble, unless the three heads per line you are running are all low volume lawn heads Hopefully they aren't I-20's with huge nozzles!

Remember, the 1/2 inch copper can only run about 6 gallons of water through it. You can only push that much water. YOu can only push as much as your SMALLEST pipe! To prevent any chance of water hammer or high velocity through the 1" mainline I would probably take it back and use 3/4".

Just my opinion.

As for the pre-assembleds...I never use them but that doesn't mean anything. We always build ours as needed.

Sprinklersolutions.net


Wednesday, March 20th 2002, 12:06pm

by RVLI

My first suggestion is that you should really go from the basement waterline. It is worth doing more work to get water from your mainline so you can have more pressure, therfore, having more sprinklers on a zone. If you still wish to come from the washer line, use 1/2 copper from the pipe to the washer, to the backflow device, then come out of the device with 3/4" PVC to your valve manifold.
Then, use the 1" Flex pipe (I am assuming poly pipe) from the valve to your sprinklers. It is ok to use the 1" pipe that you bought.
It is also worth using the valve manifolds that you can order. They are alot stronger than manifolds that you make. My suggestion is to use the ordered manifolds.

Hope this helps!!!




Tuesday, March 19th 2002, 4:39pm

by redwine

questions about backflow/sprinklersystem

I"m putting a sprinkler system in, and I have just ran a 1/2 inch copper pipe off a cold water 1/2 copper pipe that is used for the washing machine...I did'nt want to tear up my basement to run off of the main line....

they only sell 3/4 inch backflow preventers..so is it ok to go into the 3/4 backflow with 1/2 copper? and come out of it with 1/2 copper??

also,I bought 1 inch flex pipe
for the lines in the yard...is that ok? or would 3/4 be better???

(I have a small yard and I am only running 3 sprinklers max on each valve,so I should have plenty pressure)

and just 1 more question...I have seen pre assembled valve manafolds on line, but haven't found them in any stores...are they worth ordering?



Edited by - redwine on Mar 19 2002 10:44:53 PM