You are not logged in.

Reply

Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 783 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 5 posts

Tuesday, May 29th 2012, 1:49pm

by teamo

I would not use 3/4" lines. Use 1" line for everything. The only reduction in size should be at the individual heads. There are lots of options for setting up the heads. I prefer to use swing (funny) pipe for the connections to the heads. Some people use risers that are cut off at the height that they need them. There are also saddles that pierce the line and make the connections. I prefer the flexible swing pipe because I have had to move heads at certain times due to lawn or garden bed changes and the swing pip makes it easy to just dig up the connection and change the placement of the heads. You can make up a valve manifold out of pvc if you prefer but the best way is to buy a pre-made manifold with union joints. The manifolds make servicing/replacing valves much easier and sooner or later you will have to repair or replace a valve. Also don't forget a backflow preventer on the main supply to the manifold.

Friday, April 27th 2012, 5:57pm

by Central Irrigation

For ease of maintenance....use 1" for everything. If that's what your flows dictate.

Friday, April 27th 2012, 2:52pm

by GatorGuy

Jordan-,
I have a copy of the Hunter's DIY manual on my desk. It's hard to beat for consumers.
The link is at http://www.hunterindustries.com/residential-system-design-guide
You'll have to cut and paste that into your browser.

Pipe size is determined by GPM. Many, many charts available, including HERE.
The Home Depot guy threw out a rule-of-thumb idea. A lot of people use it.
A lot of people regret it.

Understand, when you do the design you might find out you are doing exactly what the guy said.
You might not. But if you do, it will be for the right reasons.

One thing to remember, too big a pipe is always much better than a too small pipe.

Friday, April 27th 2012, 2:35pm

by wsommariva

Hopefully the pros will answer, but here are my thoughts. 1 inch to the valves should be pvc. Either 1 inch or 3/4 inch from the valves should be ok, but bigger the better. That 1/2 inch from the lateral to the heads is a swing joint diameter, should be ok also. And all the heads I have have 1/2 inch inlets. I'm thinking that funny pipe may be 3/8 inch.

Since you like to read, maybe check out Hunters DIY manual. Easy reading, good stuff.

Friday, April 27th 2012, 11:48am

by Jordan (Guest)

Flow and pressure over distance

I'm going to install an inground system, myself. I bought a book and read it cover to cover. I'm mostly prepared as far as having the design layout, all measurements accounted for and about 95% of my materials sitting in my garage. However, a discussion with a fellow at Home Depot threw me for a loop. He suggested/adviced that as I use a 1" line into the valves, to use a 3/4" feed line after the valves and then tee off to a 1/2" line to finally feed the heads.
After reading a little more on this (which is not a topic covered anywhere in the "Scotts" book that I mentioned), I'm concerned about reducing the flow rate.
I won't have many turns, will be placing the valves in the zones they serve and will have a static pressure of anywhere from 60lbs. to 100lbs.
Is reducing line size something I should be concerned about?
Thanks!