Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 1209 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 7 posts

Sunday, July 31st 2011, 8:50am

by AutomaticSprinklers

Sounds like you likely have something in the line. I would take the sprinkler off and see what what the flow is coming off of the riser/swing ell. If this is minimal remove this tot he zone line and see what the flow is there. You will want to dig a hole big enough to accommodate this. One of the first things I learned on the job was that a big hole is a happy hole. The connection of the sprinkler to the zone line is usually where the clogs will be.

Saturday, July 30th 2011, 1:02pm

by fhorta (Guest)

leaks?

i dug out the entire sprinkler. ill diG dipper see if i can find obstructions. also, i mentioned earlieer when i plug the working unit with finger, the underworking unit does pop up alll the way and begins to spray the way its supposed to. t his is no longer case. bad unit comes up just a little and water squeezes/bubbles through the sprinkdler head but never pops up all the way. if i pull it up it will stay up and spray..

Thursday, July 28th 2011, 9:33pm

by AutomaticSprinklers

If you had a leak I would expect both sprinklers to operate poorly unless it was on the riser or swing ell. To check for leaks look for water bubbling up. Sounds like more of a clog or restriction in the line. You said you checked for clogs. How did you do this? I would dig the new head up unscrew it and see what kingd of flow you have. If it is minimal start by checking where the head is screwed into the zone line. Other possibility could be a root restricting the zone line. If the head in question is the first one on the line that is unlikely.

Thursday, July 28th 2011, 4:51pm

by fhorta (Guest)

leaks?

ok. i sure will. but what exactly am i looking for? so new at this. also, when i plug the working unit with finger, the underworking unit does pop up alll the way and begins to spray the way its supposed to. does this indicate something or narrrrow down probability of problem?

Thursday, July 28th 2011, 12:15pm

by wsommariva

Check for leaks at the underperforming unit.

Wednesday, July 27th 2011, 8:35pm

by fhorta (Guest)

forgot to mention

sprinklers are rotor (one is toro, the one not working good and the other is orbit).....and correction to psi required, i believe its 50 psi for each if nozzle size of 3.0. they are both long shooters. the toro sprinkler is new and already checked for clogs but found none. thanks again.

Wednesday, July 27th 2011, 8:05pm

by fhorta (Guest)

sprinkler won't pop up all the way

hello to all and thanks in advance. so glad i found this site. read as much as possible and sorry if i missed my answer already. i have a 6 station sprinkler system. they all operate separately and mostly 2 sprinklers at a time. i am having an issue with one of the stations that operate 2 sprinklers; one pops up and sprays far and wide while the other only throws a thin, weak stream. both sprinklers are designed for 35-40' distance. they both have female ends of 3/4''. i am so new at this. i already replaced the bad sprinkler but did not fix the issue. problem is that i don't know what i did with the old sprinkler and don't remember what the size was...the valve that controls this station says that it has a max psi of 150. the psi's required for the sprinklers are 30 for each. any ideas i would appreciate it so much. live in california san joaquin valley, and my lawn is drying up in those spots.