Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 1142 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 5 posts

Sunday, July 17th 2011, 6:48pm

by seansy59

There ya go! That was the common (neutral wire)! Easy fix :thumbup:

Sunday, July 17th 2011, 6:09pm

by rob

Wire nut connecting power to valves 4-7 in valve box apparently came loose. Tightened it and all is working properly.

Sunday, July 17th 2011, 3:41pm

by seansy59

A wire might have been chewed on or cut by an animal/object. Trace the wires from your controller to the valves. Also, check that the wires are secured on your timer, as if the common wire goes, they all (or most) of the valves will stop.

Sunday, July 17th 2011, 1:15pm

by Wet_Boots

check your wiring

Sunday, July 17th 2011, 12:45pm

by rob

4 Zones suddenly not working

I have a 7 zone system with an Irritrol total control 9 station controller. The system has been working fine until today when zones 4, 5, 6, and 7 are not working (whether scheduled or run as single station). Zones 1-3 still work fine. Hard to imagine 4 valves going bad all of the sudden, is there some way to test the controller to diagnose the problem? I am running them manually right now by opening the valves in the box but hoping there is a solution to be found. Thanks.