You are not logged in.

Reply

Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 1281 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 9 posts

Tuesday, March 29th 2011, 8:37am

by Wet_Boots

It should work. Will it be completely reliable in all circumstances? That depends on the zone valves always functioning, and never sticking closed. Or it depends on the mainline pipe and connections being able to withstand full supply pressure on a continual basis.

Sunday, March 27th 2011, 2:11pm

by TellyDSP (Guest)

I have the older RainBird ESP4 which has a master valve connection, however it seems this is only able to run as an "all zone" feature. It doesnt appear that would be a problem, as long as it closes off the valve when the cycle is done running. It's only 3 zones.

Am I wrong to use this master valve terminal to control the current zone valve on the "main" side of the driveway which I'll now use as a master for the two new zones, and install two new valves on that plumbing, on the far side of the driveway? (That made sense in my head, hopefully it come out clearly)

Monday, March 21st 2011, 7:58am

by Wet_Boots

That will work. Some controllers can even selectively power the "new master valve" so it only is on when the zones it feeds are on.

Friday, March 18th 2011, 4:21pm

by TellyDSP (Guest)

Could I leave the current valve that I was planning to eliminate in place as a "master" and the put the two new valves on the other side of the driveway? I suppose I would wire both valves to the master, as well as their respective zones? Would this affect the control panel at all?

Friday, March 18th 2011, 12:44pm

by Wet_Boots

Pipe is pipe - you could have an extra hundred feet or so to zone valves in the field, and no worries.

-

One thing, though, is that zone pipe is not always good for being under 24/7 water pressure. Use a master valve to feed this new "mainline" running under the driveway, and the pipe isn't exposed to continuous pressure.

Friday, March 18th 2011, 8:50am

by TellyDSP (Guest)

The control box is just inside the garage wall near the current valves. I would run the wiring through the garage to the other side. I suppose I would have to split the common wire to both sides of the driveway. Is there any issue with respect to the water supply and having the excess plumbing between valves?

Wednesday, March 16th 2011, 10:06pm

by Mitchgo

Ditto!! Don't forget the wiring!

Where is the controller located?

Is it inside the garage basically right behind the shut off and valves of the current location?

If it's in the garage you can easily run the wire up, over and through the garage rafters to the otherside of the driveway to the new valves.

Wednesday, March 16th 2011, 7:10am

by Wet_Boots

Zone valves are electric - Are you going to run wire to the far side of the drive way?

Wednesday, March 16th 2011, 5:29am

by TellyDSP (Guest)

VALVE SPACING QUESTION

I purchased a house with 2 zones and would like to add a third. The issue I have is that the new zone will be on the opposite side of a 15-20' driveway from the current valves and main. There is already a zone on that far side, so I'm wondering if I can eliminate the the current valve for that zone and move it to the other side of the driveway, while at the same time branching off the third zone from the new valve location. Would spacing valves 15-20' apart create an issue? It looks like the line running under the driveway is 3/4 - 1". For reference, I made some fine art.