Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 1554 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 4 posts

Monday, May 31st 2010, 9:47pm

by mrfixit

Have you had any plumbing work done recently? Sometime plumbers will get debris in the mainline which can keep a valve or two from shutting off. One time I came across a manifold that was jammed fullll of pebbles.

Monday, May 31st 2010, 9:32pm

by azonbuild@aol.com (Guest)

Zones are not shutting off

I have 24 seperate zones running off of two time clock controllers. Just recently, I have found that several of the zones are not shutting off. Even after shutting the controllers off and disconnecting the wiring they continue to run. The only way I am able to shut them down is by turing the backflow preventer off. How is this possible?

Sunday, May 2nd 2010, 4:33pm

by Wet_Boots

Test the resistance of the wiring

Saturday, May 1st 2010, 3:44pm

by Merv

Troubleshooting with no resolution

Helping a widow with a small problem with lawn irrigation, now becoming a big problem! Installed a few years ago by her deceased husband, is an Irritrol controller, and 6 valves, (all Rainbird). Valve 1 would not come on in the cycle. Other valves function OK. At controller, Valve #1 reads 4.6 volts when activated. My guess was the solenoid, replaced it. No change!! Read that interior of valve body may be worn, Replaced it! No Change! Ran the contoller thru full cycle of valves, only Valve #1 failed to open. Noticed that the Valve #1 at contoller has a yellow wire, but at valve- color is dull - brownish . Could this be a weathered "Yellow" or should I suspect a splice that is not holding, since it gets afternoon sun. ?(

What am I missing? Any suggestions would be most helpful :!: