Dear visitor, welcome to SPRINKLER TALK FORUM - You Got Questions, We've Got Answers. If this is your first visit here, please read the Help. It explains how this page works. You must be registered before you can use all the page's features. Please use the registration form, to register here or read more information about the registration process. If you are already registered, please login here.

Attention: The last reply to this post was 4183 days ago. The thread may already be out of date. Please consider creating a new thread.

Message information
Message
Settings
Automatically converts internet addresses into links by adding [url] and [/url] around them.
Smiley code in your message such as :) is automatically displayed as image.
You can use BBCode to format your message, if this option is enabled.
Security measure

Please enter the letters that are shown in the picture below (without spaces, and upper or lower case can be used).

The last 2 posts

Monday, May 12th 2003, 9:50am

by Rays Sprinklers

Well there are several things that could go wrong. First go to the nozzles with a small
flat blade screw driver, and you will notice that there is a metal screw, insert the screw driver
and make sure that it is open all the way. How many heads are on that line?? What is your GPM.

It might just be the nozzle.
Sometimes they dont actually make 15'

Ray
Ray's Above and Beyond Automatic Lawn Sprinkelrs


Raymond Padula Jr.

Friday, May 24th 2002, 7:32am

by bobe

Toro 570 Sprinkler Radius

I have installed Toro 570 15' radius fixed heads, and noticed that the radius was only about 13'. I have plenty of pressure at the head (45 - 50 psig), and see no problem with the overall design (1" pipe, 3/4 HP pump drawing from an 8' deep well).